MeiTrack VT310 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Navigateurs MeiTrack VT310. Meiligao_GPRS_Communication_Protocol_GT30i GT60 VT300 Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 21
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Meiligao GPRS Communication Protocol
Between GPS Tracker and Server
Version 2.00
GT30i
GT60
VT300
VT310
VT400
Change Version
Reason of Change
Date
V1.00
Initial Document
2005-6-25
V1.01
Addition of Alarms
2006-10-8
V1.02
Addition of Output Control
Addition of Stats in GPRS String
2007-1-26
V1.03
Add command 4107/4207/4126/4130/4131/4132/9016
VT310 integrated
Change 4116
Delete 9014
2008-7-10
V1.04
Add 5114
Add AD of VT310
2008-12-2
V1.05
Add Power-cut Alarm
Add Buzzer Control for GT60
2009-02-04
V1.06
Add 9001 to get SN and IMEI
Add 5101/5115/5199
2009-3-18
V1.07
Add 4136
2009-08-03
V1.45
Change 4136
Add 4902/5503
2009-09-15
V1.46
Wording Correction
2010-06-03
V1.47
Delete GT30/GT30X. Add GT30i
2010-07-15
V2.0
Delete 4107/4207
Modify 4106/4113/4116/9999/Annex 1(base ID, CSQ, journey)
Add 4135/4155/4302/4303/4351
2011-02-19
Add 4150
2011-04-14
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1

Meiligao GPRS Communication Protocol Between GPS Tracker and Server Version 2.00 GT30i GT60 VT300 VT310 VT400 Change Version Reason of Ch

Page 2

- 10 - Response: $$<L><ID><0x4115><Flag><checksum>\r\n Note: Flag =0x00, failure response; =0x01, success response.

Page 3

- 11 - Above command will enable alarms when Input1 is active, Input2 is inactive, Input3 is either active or inactive, Input4 is active and Input5

Page 4

- 12 - 16. Log by Interval – 0x4131 Command: @@<L><ID><0x4131><data><checksum>\r\n Description: Set time interval for

Page 5 - 6. Speeding Alarm – 0x4105

- 13 - Response: $$<L><ID><0x4135><Flag><checksum> \r\n Example: 24 24 00 12 40 10 47 20 21 3F FF 41 35 01 F8 51 0D 0A

Page 6 - 7. Movement Alarm – 0x4106

- 14 - =1, TCP =2, UDP Example: 40 40 00 2E 40 10 47 20 21 3F FF 41 55 31 2C 31 31 33 2E 39 32 2E 31 31 31 2E 32 32 31 2C 38 30 35 32 2C 63 6D 6E 65

Page 7 - 9. Initialization – 0x4110

- 15 - =0,cancle =[1,4294967295] meter(s) Distance interval is suggested to be set above 300 meters. Example: 40 40 00 14 40 20 50 20 81 4F FF 43 03

Page 8 - 10. Sleep Mode – 0x4113

- 16 - Response: $$<L><ID><0x5199><Flag><checksum> \r\n Note: Flag =0x00, failure response; =0x01, success response.

Page 9

- 17 - Description: To get the authorized phone number. Note: Button no should be 0x01, 0x02 or 0x03. If button no is 0xff, it will read all authori

Page 10

- 18 - =0x02 Call B button is pressed / Input 2 active =0x03 Call C button is pressed / Input 3 active =0x04 Input 4 active =0x05 Input 5 active =0x

Page 11 - 14. Power Down – 0x4126

- 19 - Annex 1: Description of data

Page 12 - 17. Time Zone – 0x4132

- 2 - I. Command Format

Page 13

- 20 - (3) HDOP, in ASCII code, 0.5-99.9. HDOP is blank when the tracking unit has no GPS fix. (4) Altitude, in decimal string. (5) State: Status

Page 14

- 21 - For VT400 Bit0: Status of Out1 If Bit0=0: Out1 is closed; Bit0=1:Out1 is open. Bit1: Status of Out2 If Bit1=0: Out2 is closed; Bit1=1:Out2 i

Page 16 - 29. Read Interval – 0x9002

- 4 - III. Command Details

Page 17 - 32. Alarms – 0x9999

- 5 - Note: Flag =0x00, failure response; =0x01, success response. Once the interval is successfully set, the tracker will send the following positi

Page 18

- 6 - ……. =0x0A, speed limit is set to 100km/h; ……. =0x14, speed limit is set to 200km/h. Max speed limit is 200km/h. Example: 40 40 00 12 12 34 56

Page 19 - Checksum

- 7 - ABCDEFGHIJ (defaulted as 0x01 0x00 0x00 0x00 0x01 0x00 0x00 0x00 0x00 0x01): A=0x00, turn off the function of replying with an SMS position re

Page 20

- 8 - 10. Sleep Mode – 0x4113 Command: @@<L><ID><0x4113><power-saving level (1 byte in hex code)><checksum>\r\n Descr

Page 21

- 9 - C=0x01, open output (OUT3) -connect to GND; C=0x02, remain previous status. D=0x00, close output (OUT4) -open drain; D=0x01, open output (OUT4

Commentaires sur ces manuels

Pas de commentaire